I broke my rule of using the Ubuntu version one step backward from the current development release. My main interest is the stable ntfs driver with write capability. The upgrade went smooth except for a minor issue related to shared-mime-info package and a custom package (freemind). I reported the fix here.
We confirmed that the free ESXi version does not allow SNMP gets, only traps. The original script was taken from here: http://communities.vmware.com/docs/DOC-7170 Modified script: http://mirakulo.com/pub/esxi/check_esx_wbmem.py We added Fan and power supply, hinted from this page: http://www.stephenjc.com/2009/01/whatsup-vmware-esxi-monitor-these.html Use this guide to add the Data source: http://www.zenoss.com/community/docs/howtos/create-modify-nagios-templates Added as template under: /Devices /Server /VMWare /ESXi /Templates /esxi-monitor /check_esx_wbmem Name: check_esx_wbmem Source Type: Command Enable true Use SSH false Component: blank Event class: /VMWare/ESXi Severity: Error Cycle time: 60 Parser: auto Command template: /usr/local/zenoss/python/bin/python /opt/zenoss/libexec/check_esx_wbmem.py https://${dev/manageIp}:5989 root passwd To bind this template to ESXi nodes, go to the device: Example: /Devices /Server /VMWare /ESXi /esxi-01.prod.corp.org then to its temp