Skip to main content

Upgrade: Ubuntu Edgy (6.10) to Feisty (7.04)

I broke my rule of using the Ubuntu version one step backward from the current development release. My main interest is the stable ntfs driver with write capability. The upgrade went smooth except for a minor issue related to shared-mime-info package and a custom package (freemind). I reported the fix here.

Comments

Popular posts from this blog

ld: unrecognized option '--hash-style=both'

gcc -Wl,-Map=contiki.map,-export-dynamic testv6.co obj_linux-native/socketdev_listener.o \ contiki-linux-native.a -o testv6.linux-native /usr/local/bin/ld: unrecognized option '--hash-style=both' /usr/local/bin/ld: use the --help option for usage information collect2: ld returned 1 exit status If you look closely, the error is something related to the local gcc not using the host's linker (ld). $ which gcc /usr/bin/gcc $ which ld /usr/local/bin/ld For some reason, I messed my compiler path. To synchronized gcc to use the host's dynamic linker (i.e. /usr/bin/ld ), set the environment variable COMPILER_PATH to /usr/bin . $ export COMPILER_PATH=/usr/bin $ echo $COMPILER_PATH /usr/bin $ gcc -print-prog-name=ld /usr/bin/ld

Ebay scammer

+639056538210 09056538210 Gene Paminiano Claiming to be his wife: Ramona Carmen Paminiano City States savings account# 011-22-001124-3 TIP: Do not push with the transaction without hearing the seller/buyer's voice on the phone. Record the conversation for publicity purposes.

Zenoss: monitor free VMWare ESXi version

We confirmed that the free ESXi version does not allow SNMP gets, only traps. The original script was taken from here: http://communities.vmware.com/docs/DOC-7170 Modified script: http://mirakulo.com/pub/esxi/check_esx_wbmem.py We added Fan and power supply, hinted from this page: http://www.stephenjc.com/2009/01/whatsup-vmware-esxi-monitor-these.html Use this guide to add the Data source: http://www.zenoss.com/community/docs/howtos/create-modify-nagios-templates Added as template under: /Devices /Server /VMWare /ESXi /Templates /esxi-monitor /check_esx_wbmem Name: check_esx_wbmem Source Type: Command Enable true Use SSH false Component: blank Event class: /VMWare/ESXi Severity: Error Cycle time: 60 Parser: auto Command template: /usr/local/zenoss/python/bin/python /opt/zenoss/libexec/check_esx_wbmem.py https://${dev/manageIp}:5989 root passwd To bind this template to ESXi nodes, go to the device: Example: /Devices /Server /VMWare /ESXi /esxi-01.prod.corp.org then to its temp...